Solid fuel loading sets
- Fully pre-assembled unit for return temperature maintenance in solid fuel boiler systems. The temperature is kept constant by means of an integrated thermal valve
- For external activation
- Gravity operation in case of power failure or pump failure
- Fully pre-assembled unit for return temperature maintenance in solid fuel boiler systems. The temperature is maintained electronically by means of an actuator
- Gravity operation in case of power failure or pump failure
- Integrated check valve, which can be switched off from the outside
- Fully pre-assembled unit for return temperature maintenance in solid fuel boiler systems. The temperature is maintained electronically by means of an actuator
- Gravity operation in case of power failure or pump failure
- Integrated check valve, which can be switched off from the outside
- Technical data:
- Operating voltage: 230V/AC, 50 Hz
- Boiler output max.: 100 kW
- Pre-assembled valve unit for solid fuel buffer storage systems to maintain the boiler return temperature. Due to optimal boiler return temperature, falling below dew point and boiler sooting is prevented, which means that there is less environmental pollution and the service life of the boiler is extended. Using the loading valve unit, stratification in buffer storage can also be improved.
Technical data: - Operating voltage: 230 V / AC, 50 Hz
- Max. flow rate: 2600 L/h
- Pre-assembled valve unit for solid fuel buffer storage systems to maintain the boiler return temperature. Due to optimal boiler return temperature, falling below dew point and boiler sooting is prevented, which means that there is less environmental pollution and the service life of the boiler is extended. Using the loading valve unit, stratification in buffer storage can also be improved.
Technical data: - Operating voltage: 230 V / AC, 50 Hz
- Max. flow rate: 2600 L/h
- Return flow boost for solid fuel boilers as well as wood burning systems and chimney / oven heaters.
Prepared for assembly under PAW module distributors. - With Wilo Para SC 25 /6-43 pump
- Check valve in the flow of the thermal control valve
- Flow:
1 x flow pump flange ball valve with thermometer handwheel (thermometer ring, red, 0-120°C) - 2 x union nut and seal
- 1 x screw connection DN 20 (3/4")
- For return flow control for solid boiler systems
- Fixed to 60°C
Flow:
1x flow pump flange ball valve with thermometer handwheel (thermometer ring red, 0-120°C) and adjustable check valve by turning handwheel 45°
1 x spacer
1 x screw connection
1x T-piece for mixer
1x pump
Return:
1 x return pump flange ball valve with thermometer handwheel (thermometer ring, blue, 0-120°C)
2 x union nut and seal
1 x screw connection
1x 3-way thermostatic mixing valve
Technical data: - Output: up to 32 kW
- For return flow control for solid boiler systems
- Can be set from 20°C to 80°C
Flow:
1x flow pump flange ball valve with thermometer handwheel (thermometer ring red, 0-120°C) and adjustable check valve by turning handwheel 45°
1 x spacer
1 x screw connection
1x T-piece for mixer
1x pump
Return:
1 x return pump flange ball valve with thermometer handwheel (thermometer ring, blue, 0-120°C)
2 x union nut and seal
1 x screw connection
1 x three-way mixing valve with fixed setpoint actuator ACC30
Technical data: - Output: up to 50 kW
- Installation in solid fuel fireplaces for efficient loading of Buffer tanks
- To protect the boiler from return temperatures that are too low
- To maintain a high and stable return temperature
- Return flow boost for solid fuel boilers as well as wood burning systems and chimney / oven heaters.
Prepared for assembly under PAW module distributors. - With Wilo Para SC 25 /6-43 pump
- Check valve in the flow of the thermal control valve
- Return flow boost for solid fuel boilers as well as wood burning systems and chimney / oven heaters.
Prepared for assembly under PAW module distributors. - With Wilo Para SC 25 /6-43 pump
- Check valve in the flow of the thermal control valve
- With actuator + fixed value control ACC30, setting range: 20° to 80°C
- For return flow control for solids boiler systems
Flow:
1 x flow pump flange ball valve with thermometer handwheel (thermometer ring, red)
2 x union nut and seal
1 x screw connection
Return:
1 x return pump flange ball valve with thermometer handwheel (thermometer ring, blue)
1 x check valve
1 x screw connection
1 x three-way mixing valve with actuator