Motorised solar zone valves

10 / 10
Hauptbild
Multiple variants
Two-way zone valve, Solar, IT
Immediately available
  • No limit switch
    For use in closed Heating and Solar circuits. "Open/close" function for shut-off or Changeover switch.
    Normally closed (2-way), normally open AB-B (3-way).
    They can be operated manually via an integrated lever for filling, flushing, venting and draining the system.
    Technical data:
  • Operating pressure max.: 10 bar
  • Max. differential pressure:
    - DN 15 (1/2") = 1.4 bar
    - DN 20 (3/4") = 0.7 bar
    - DN 25 (1") = 0.6 bar
Hauptbild
Multiple variants
Two-way zone valve, Solar, with limit switch
Immediately available
  • For use in closed Heating and Solar circuits. "Open/close" function for shut-off or Changeover switch.
    Normally closed (2-way), normally open AB-B (3-way).
    They can be operated manually via an integrated lever for filling, flushing, venting and draining the system.
    Technical data:
  • Operating pressure max.: 10 bar
  • Max. differential pressure:
    - DN 15 (1/2") = 1.4 bar
    - DN 20 (3/4") = 0.7 bar
    - DN 25 (1") = 0.6 bar
Hauptbild
Multiple variants
Three-way zone valve, Solar
Immediately available
  • No limit switch
    For use in closed Heating and Solar circuits. "Open/close" function for shut-off or Changeover switch.
    Normally closed (2-way), normally open AB-B (3-way).
    They can be operated manually via an integrated lever for filling, flushing, venting and draining the system.
    Technical data:
  • Operating pressure max.: 10 bar
  • Max. differential pressure:
    - DN 15 (1/2") = 1.4 bar
    - DN 20 (3/4") = 0.7 bar
    - DN 25 (1") = 0.6 bar
Hauptbild
Multiple variants
Three-way zone valve, Solar, with limit switch
Immediately available
  • 3-way valve with limit switch
    For use in closed Heating and Solar circuits. "Open/close" function for shut-off or Changeover switch.
    Normally closed (2-way), normally open AB-B (3-way).
    They can be operated manually via an integrated lever for filling, flushing, venting and draining the system.
    Technical data:
  • Operating pressure max.: 10 bar
  • Max. differential pressure:
    - DN 15 (1/2") = 1.4 bar
    - DN 20 (3/4") = 0.7 bar
    - DN 25 (1") = 0.6 bar
Hauptbild
Multiple variants
Two-way zone valve, Solar, external thread
Immediately available
  • No limit switch
    For use in closed Heating and Solar circuits. "Open/close" function for shut-off or Changeover switch.
    Normally closed (2-way), normally open AB-B (3-way).
    They can be operated manually via an integrated lever for filling, flushing, venting and draining the system.
    Technical data:
  • Operating pressure max.: 10 bar
  • Max. differential pressure:
    - DN 15 (1/2") = 1.4 bar
    - DN 20 (3/4") = 0.7 bar
    - DN 25 (1") = 0.6 bar
Hauptbild
Multiple variants
Three-way zone valve, Solar, external thread
Immediately available
  • No limit switch
    For use in closed Heating and Solar circuits. "Open/close" function for shut-off or Changeover switch.
    Normally closed (2-way), normally open AB-B (3-way).
    They can be operated manually via an integrated lever for filling, flushing, venting and draining the system.
    Technical data:
  • Operating pressure max.: 10 bar
  • Max. differential pressure:
    - DN 15 (1/2") = 1.4 bar
    - DN 20 (3/4") = 0.7 bar
    - DN 25 (1") = 0.6 bar
Hauptbild
Multiple variants
Motorised 2-way zone valves (with return spring) - solar
Immediately available
  • The zone valves are installed in closed circuits in Heating and solar systems.
    With manual operation, lockable in centre position
  • With integrated limit switch
    Technical data:
  • Power consumption: 6W
Hauptbild
Multiple variants
Motorised 3-way zone valves (with return spring) - solar
Immediately available
  • The zone valves are installed in closed circuits in Heating and solar systems.
    With manual operation, lockable in centre position
  • With integrated limit switch
    Technical data:
  • Power consumption: 6W
Hauptbild
Multiple variants
Motorised 3-way zone valves (with return spring) - solar, ET
Immediately available
  • The zone valves are installed in closed circuits in Heating and solar systems.
    With manual operation, lockable in centre position
  • With integrated limit switch
    Technical data:
  • Power consumption: 6W
Hauptbild
90 050 62
5x 3-way zone valve Orkli DN25(1") IG, without limit switch, 230V + 1x free of charge
Immediately available
  • Consisting of 6x 3-way zone valve
  • Currentless DOWN to B closed
  • Without limit switch