Bottle systems and Accesories

31 / 31
Hauptbild
Multiple variants
GOK cylinder system with OPSO/UPSO, type MUV, with manual changeover unit
Currently not in stock
  • For connection to gas cylinders with a filling weight of 33 kg, for pressure regulation to the nominal pressure of the gas appliance
  • Also suitable for commercial use
  • Cylinders can be changed without interrupting operation
Hauptbild
Multiple variants
GOK cylinder system with OPSO/UPSO, type AUV, with automatic switchover device
Immediately available
  • For connection to gas cylinders with a filling weight of 33 kg, for pressure regulation to the nominal pressure of the gas appliance
  • Also suitable for commercial use
  • Cylinders can be changed without interrupting operation
Hauptbild
Multiple variants
Hose cable for multi-bottle systems
Immediately available
  • High-pressure PS 30, DIN-DVGW-tested
  • Hose lines are equipped with a clip (except KLF)
    Connections:
  • On one side, large-bottle (GF), small-bottle (KLF) connection or combi (union nut), on the other large-bottle (GF) external thread or RST
Hauptbild
Multiple variants
Cylinder systems with OPSO, type MUV, with manual Changeover valves
Immediately available
  • For connection to gas cylinders with a filling weight of 33 kg, for pressure regulation to the nominal pressure of the gas appliance
  • Conformity:
    - Individual fittings with DIN-DVGW or DVGW type examination certificate or EU type examination certificate GGV
    Note:
    The dimensioning and design of the LPG system (selection of gas flow monitor, nominal flow rate, nominal diameter, etc.) must be carried out in accordance with TRF.
    Technical data:
  • Max. inlet pressure: 16 bar
Hauptbild
Multiple variants
Cylinder system with OPSO, with automatic switchover device
Immediately available
  • For connection to gas cylinders with a filling weight of 33 kg, for pressure regulation to the nominal pressure of the gas appliance
  • Conformity:
    - Individual fittings with DIN-DVGW or DVGW type examination certificate or EU type examination certificate GGV
    Note:
    The dimensioning and design of the LPG system (selection of gas flow monitor, nominal flow rate, nominal diameter, etc.) must be carried out in accordance with TRF.
    Technical data:
  • Max. inlet pressure: 16 bar
Hauptbild
Multiple variants
Low-pressure controller model EN61-DS PS 16 bar
Immediately available
  • Overpressure safety device S2SR for protecting the consuming devices from impermissibly high pressure
  • Viewing display (green/red) with visual signal (red) in the event of output pressures over 80 mbar
  • Thermal shut-off device for automatic shut-off of the gas flow in the event of a rise in temperature to over 100°C
Hauptbild
58 000 04
Changeover valves Automatic type AUV 12kg/h 1.5 bar GFxAG GFxGF
Immediately available
  • Output: 12 kg/h
  • Input pressure: max. 16 bar
  • With control knob
Hauptbild
58 000 15
Stove connection set Pro 1.5 kg/h 50 mbar, for domestic appliances
Immediately available
  • For connection to gas cylinders, for pressure regulation based on nominal pressure of the gas appliance
  • For connecting a household appliance, e.g. stove to the gas cylinder
  • According to TRF, gas appliances with a stainless steel corrugated hose line up to 2000 mm in length may be connected directly to the pressure regulator
    Stainless steel corrugated hose lines do not need to be replaced recurrently as they are not subject to ageing
Hauptbild
58 000 16
Stainless steel corrugated hose line type MWS, G1/4"LH-ÜWM x IT Rp1/2", length 1000 mm
Immediately available
  • For the stress-free connection of fittings to consumer appliances or pipelines
  • Maximum permissible pressure: PS 1 bar
  • DN 8 (1/4") LH union nut x IG RP DN 15 (1/2")
Hauptbild
58 000 21
Single cylinder system for small cylinders, type EN61-DS, KLF x G1/4" LH-ÜWM, 50 mbar, 1.5 kg/h
Only a few items left in stock
  • For connection to gas cylinders, for pressure regulation based on nominal pressure of the gas appliance
    - Set for the connection of a mobile interior heating device
  • Consisting of:
    - Low pressure controller type EN61-DS 1.5 kg/h 50 mbar
    - Medium pressure hose line KLF x G DN8 (¼“) LH-union nut 400 mm
    - MiniTool (53 001 71)
  • Conformity:
    - Individual fittings DIN-DVGW or DVGW tested, EC type examination
Hauptbild
58 001 10
Liquid gas bottle low pressure control KLF R1/4" 1,5kg/h 50mbar up to 11 kg/h
Immediately available
  • For bottle systems with thermal shut-off device and control manometer, fixed
  • With control manometer for testing bottle connection and pipe system tightness
  • Thermal shut-off device for automatic shut-off of the gas flow in the event of a rise in temperature to over 100°C, back pressure safe to 16 bar
Hauptbild
58 001 28
High pressure G hose small bottle connection 300 mm
Immediately available
  • High-pressure PS 30, DIN-DVGW-tested
  • Hose lines are equipped with a clip (except KLF)
    Connections:
  • On one side, large-bottle (GF), small-bottle (KLF) connection or combi (union nut), on the other large-bottle (GF) external thread or RST
Hauptbild
58 001 44
Emergency supply fitting combination A x3/8”lft.x 2000mm
Currently not in stock
  • Connection directly to the pre-stage regulator for emergency supply of the liquid gas tank system from a gas cylinder
  • Feed directly into the pre-stage regulator with emergency supply connection DN 10 (3/8") left union nut
  • Consisting of:
    - Hose breakage protection Komb.-A x DN 10 (3/8") left AG
    - Connecting hose on both sides DN 10 (3/8") left union nut x 2000 mm long,
Hauptbild
58 001 61
Low pressure regulator with overpressure. Combi x 1/4``LH, PN 16
Immediately available
  • With integrated overpressure safety device (OSD) for protection
  • Viewing display (green/red) with visual signal (red) in the event of output pressures over 80 mbar
  • PS 16
    Connections:
Hauptbild
58 001 83
Tee for multi-bottle plants
Immediately available
  • For multi-bottle systems
  • Large bottle ET x combination union nut x large bottle ET
Hauptbild
58 001 84
Connection hose PB 30 - 400mm
Immediately available
  • For multi-bottle systems
  • 2 x combi union nuts
  • Length: 400mm
Hauptbild
58 001 85
Large bottle hose PB 30 x LB X RST 12 mm X 400 mm
Immediately available
  • High-pressure PS 30, DIN-DVGW-tested
  • Hose lines are equipped with a clip (except KLF)
    Connections:
  • On one side, large-bottle (GF), small-bottle (KLF) connection or combi (union nut), on the other large-bottle (GF) external thread or RST
Hauptbild
58 002 03
Cooker connection set Basic, 1.5kg/h, 50mbar, for domestic systems
Immediately available
  • For connection to gas cylinders, for pressure regulation to the nominal pressure of the gas appliance
  • Consisting of:
    - Low pressure regulator type EN61-DS with overpressure safety device S2SR (ÜDS)
    - Visual indicator
    - Thermal Isolating fittings "T" (TAE)
    - Pressure gauge
    - Medium-pressure hose (rubber with textile inlay, cold-resistant to -30°C, hose dimensions 6.3 x 3.5 mm) DN 8 (1/4") LH-ÜM x RVS 8 x 400 mm
    - Connecting pipe and Angle screw-on fitting type WAI IG DN 15 (1/2") x RVS 8
  • Conformity:
    - Individual fittings with DIN-DVGW or DVGW type examination certificate or EU type examination certificate DGR, GGV
Hauptbild
58 002 04
Alu seal for 33 kg bottles
Immediately available
  • Replacement seal, large flange, alum.
Hauptbild
58 002 05
Plastic seal combi connection (5/11/33 kg)
Immediately available
  • Spare gasket combination, plastic
Hauptbild
58 002 09
Seal case for liquid gas bottle regulators 120 off
Immediately available
  • Consisting of:
  • 20 x 16.5 x 10.0 x 3.5 mm, NBR: small bottle
  • 20 x 18.0 x 11.7 x 2.0 mm, aluminium: large bottle
Hauptbild
58 003 24
Cap for 5/11 kg propane gas bottle
Immediately available
  • For small butane gas bottes with 5 kg and 11 kg filling weight
  • With fixing bracket
Hauptbild
58 003 25
Brass tank lock without key
Immediately available
  • Made of brass
  • For cover hoods and dome covers of stationary liquid gas storage containers
  • No key
Hauptbild
58 003 26
Key for tank lock
Immediately available
  • Made of brass
  • For cover hoods and dome covers of stationary liquid gas storage containers
  • No key
Hauptbild
58 004 17
Double shut-off block with Quick-closing valves GF x ET-GF x GF
Currently not in stock - Time of delivery: approx. 4-5 weeks
  • Input pressure: max. 16 bar
  • For installation in multi-cylinder systems
  • Fixing option for support rail
Hauptbild
58 004 23
Gas hose 300 mm 30 bar Combi connection on one side 12 mm pipe support on the other side
Immediately available
Hauptbild
58 004 35
Automat. changeover valve type AUV PS 16 bar, 6 kg/h, pd=0.5-1.2 bar, 2x GF x ET GF x GF
Immediately available
  • Output: 6 kg/h
  • Input pressure: max. 16 bar
  • With rotary knob
Hauptbild
58 004 69
Changeover valve MUV PS 25bar
Immediately available
  • Input pressure: max. 25 bar
  • For manual switching in multi-cylinder systems
  • Withdrawal takes place alternately, a cylinder can be changed without interrupting operation
Hauptbild
Multiple variants
Small bottle system
Immediately available
  • For connection to gas cylinders (5.11 kg), for pressure regulation to the nominal pressure of the gas appliance
  • Removal from both sides, cylinders can be changed without interrupting operation
  • Pressure gauge for checking the system for leaks
Hauptbild
Multiple variants
LPG seal case, 235-pieces
Immediately available
  • Consisting of:
  • 20 x 16.5 x 10.0 x 3.5 mm, NBR: small bottle
  • 20 x 18.0 x 11.7 x 2.0 mm, aluminium: large bottle
Hauptbild
Multiple variants
U-lock, brass
Immediately available
  • Made of brass
  • For cover hoods and dome covers of stationary liquid gas storage containers
  • No key