Bottle systems and Accesories
- For connection to gas cylinders with a filling weight of 33 kg, for pressure regulation to the nominal pressure of the gas appliance
- Also suitable for commercial use
- Cylinders can be changed without interrupting operation
- For connection to gas cylinders with a filling weight of 33 kg, for pressure regulation to the nominal pressure of the gas appliance
- Also suitable for commercial use
- Cylinders can be changed without interrupting operation
- High-pressure PS 30, DIN-DVGW-tested
- Hose lines are equipped with a clip (except KLF)
Connections: - On one side, large-bottle (GF), small-bottle (KLF) connection or combi (union nut), on the other large-bottle (GF) external thread or RST
- For connection to gas cylinders with a filling weight of 33 kg, for pressure regulation to the nominal pressure of the gas appliance
- Conformity:
- Individual fittings with DIN-DVGW or DVGW type examination certificate or EU type examination certificate GGV
Note:
The dimensioning and design of the LPG system (selection of gas flow monitor, nominal flow rate, nominal diameter, etc.) must be carried out in accordance with TRF.
Technical data: - Max. inlet pressure: 16 bar
- For connection to gas cylinders with a filling weight of 33 kg, for pressure regulation to the nominal pressure of the gas appliance
- Conformity:
- Individual fittings with DIN-DVGW or DVGW type examination certificate or EU type examination certificate GGV
Note:
The dimensioning and design of the LPG system (selection of gas flow monitor, nominal flow rate, nominal diameter, etc.) must be carried out in accordance with TRF.
Technical data: - Max. inlet pressure: 16 bar
- Overpressure safety device S2SR for protecting the consuming devices from impermissibly high pressure
- Viewing display (green/red) with visual signal (red) in the event of output pressures over 80 mbar
- Thermal shut-off device for automatic shut-off of the gas flow in the event of a rise in temperature to over 100°C
- Output: 12 kg/h
- Input pressure: max. 16 bar
- With control knob
- For connection to gas cylinders, for pressure regulation based on nominal pressure of the gas appliance
- For connecting a household appliance, e.g. stove to the gas cylinder
- According to TRF, gas appliances with a stainless steel corrugated hose line up to 2000 mm in length may be connected directly to the pressure regulator
Stainless steel corrugated hose lines do not need to be replaced recurrently as they are not subject to ageing
- For the stress-free connection of fittings to consumer appliances or pipelines
- Maximum permissible pressure: PS 1 bar
- DN 8 (1/4") LH union nut x IG RP DN 15 (1/2")
- For connection to gas cylinders, for pressure regulation based on nominal pressure of the gas appliance
- Set for the connection of a mobile interior heating device - Consisting of:
- Low pressure controller type EN61-DS 1.5 kg/h 50 mbar
- Medium pressure hose line KLF x G DN8 (¼“) LH-union nut 400 mm
- MiniTool (53 001 71) - Conformity:
- Individual fittings DIN-DVGW or DVGW tested, EC type examination
- For bottle systems with thermal shut-off device and control manometer, fixed
- With control manometer for testing bottle connection and pipe system tightness
- Thermal shut-off device for automatic shut-off of the gas flow in the event of a rise in temperature to over 100°C, back pressure safe to 16 bar
- High-pressure PS 30, DIN-DVGW-tested
- Hose lines are equipped with a clip (except KLF)
Connections: - On one side, large-bottle (GF), small-bottle (KLF) connection or combi (union nut), on the other large-bottle (GF) external thread or RST
- Connection directly to the pre-stage regulator for emergency supply of the liquid gas tank system from a gas cylinder
- Feed directly into the pre-stage regulator with emergency supply connection DN 10 (3/8") left union nut
- Consisting of:
- Hose breakage protection Komb.-A x DN 10 (3/8") left AG
- Connecting hose on both sides DN 10 (3/8") left union nut x 2000 mm long,
- With integrated overpressure safety device (OSD) for protection
- Viewing display (green/red) with visual signal (red) in the event of output pressures over 80 mbar
- PS 16
Connections:
- For multi-bottle systems
- Large bottle ET x combination union nut x large bottle ET
- For multi-bottle systems
- 2 x combi union nuts
- Length: 400mm
- High-pressure PS 30, DIN-DVGW-tested
- Hose lines are equipped with a clip (except KLF)
Connections: - On one side, large-bottle (GF), small-bottle (KLF) connection or combi (union nut), on the other large-bottle (GF) external thread or RST
- For connection to gas cylinders, for pressure regulation to the nominal pressure of the gas appliance
- Consisting of:
- Low pressure regulator type EN61-DS with overpressure safety device S2SR (ÜDS)
- Visual indicator
- Thermal Isolating fittings "T" (TAE)
- Pressure gauge
- Medium-pressure hose (rubber with textile inlay, cold-resistant to -30°C, hose dimensions 6.3 x 3.5 mm) DN 8 (1/4") LH-ÜM x RVS 8 x 400 mm
- Connecting pipe and Angle screw-on fitting type WAI IG DN 15 (1/2") x RVS 8 - Conformity:
- Individual fittings with DIN-DVGW or DVGW type examination certificate or EU type examination certificate DGR, GGV
- Replacement seal, large flange, alum.
- Spare gasket combination, plastic
- Consisting of:
- 20 x 16.5 x 10.0 x 3.5 mm, NBR: small bottle
- 20 x 18.0 x 11.7 x 2.0 mm, aluminium: large bottle
- For small butane gas bottes with 5 kg and 11 kg filling weight
- With fixing bracket
- Made of brass
- For cover hoods and dome covers of stationary liquid gas storage containers
- No key
- Made of brass
- For cover hoods and dome covers of stationary liquid gas storage containers
- No key
- Input pressure: max. 16 bar
- For installation in multi-cylinder systems
- Fixing option for support rail
- Output: 6 kg/h
- Input pressure: max. 16 bar
- With rotary knob
- Input pressure: max. 25 bar
- For manual switching in multi-cylinder systems
- Withdrawal takes place alternately, a cylinder can be changed without interrupting operation
- For connection to gas cylinders (5.11 kg), for pressure regulation to the nominal pressure of the gas appliance
- Removal from both sides, cylinders can be changed without interrupting operation
- Pressure gauge for checking the system for leaks
- Consisting of:
- 20 x 16.5 x 10.0 x 3.5 mm, NBR: small bottle
- 20 x 18.0 x 11.7 x 2.0 mm, aluminium: large bottle
- Made of brass
- For cover hoods and dome covers of stationary liquid gas storage containers
- No key