Photovoltaics
- Cable colour: black- Conductor cross-section: 6 mm²- Plug connector design: WM4 C / MC4 ...
- Protection class: IP65, when closed, IP2x open, IP67, IP68- Continuous operating temperature: -40°C to 85°C- Rated voltage: 1500 V DC- Rated current: 30 A- External cable diameter: 5.4 mm to 7.6 mm- Conductor connection cross-section: 4 mm² to 6 mm²- Cable type: EN 50618:2014- PU = 10 ...
- Protection class: IP65, IP67, IP2x open- Continuous operating temperature: -40°C to 85°C- Rated voltage: 1500 V DC- Rated current: 35 A- Thread: M12- External cable diameter: 5.5 mm to 7 mm- Conductor connection cross-section: 4 mm² to 6 mm²- Cable type: EN 50618:2014- PU = 100 ...
- PU = 100 ...
- Protection class: IP20- Operating temperature: -40 °C to +85 °C- Category: SPD TYPE 1CA- Certificate no. (cURus): E354261- Voltage type: DC- Rated voltage UN: 550V- Visual function indicator: green = ok, red = arrester defective, replace- Leakage current In (8/20 µs): 20 kA- Leakage current, ma ...
- Connection box: IP68 with 3 bypass diodes
- Connection cable: 2 x 2000 mm, 4 mm², MC4 compatible
- Cell material: monocrystalline
- Set consisting of 1x plug + 1x socket- Protection class: IP65, when closed, IP2x open, IP67, IP68- Continuous operating temperature: -40°C to 85°C- Rated voltage: 1500 V DC- Rated current: 30 A- External cable diameter: 5.4 mm to 7.6 mm- Conductor connection cross-section: 4 mm² to 6 mm²- Cabl ...
- 1/4" Torque screwdriver gun with Rapidaptor quick-change chuck: 3.0-6.0 Nm
- 1/2" Socket wrench inserts with cut-out, external hexagon, length (mm): SW 17, 76
- 1/4" Bit holder with Rapidaptor quick-change chuck, magnetic, max. torque (Nm): 10
- Suitable for combination arrester ProTec T1
- With optional remote signalling contact (M)
- Protection class: IP20- Type 2 according to EN 61643-31:2019- With visual indicator- Pluggable version- Response time: < 25 ns- For snapping onto the 35 mm busbar system- Protection level (8/20 µs): 500 V/AC- Highest continuous voltage: 125 V/DC- Nominal-/limit-leakage current [L-N]/[N-PE]: 20/50 ...
- Protection class: IP20- Type 2 according to EN 61643-31:2019- With visual indicator- Pluggable version- Response time: < 25 ns- For snapping onto the 35 mm busbar system- Protection level (8/20 µs): 900 V/AC- Highest continuous voltage: 250 V/DC- Nominal-/limit-leakage current [L-N]/[N-PE]: 20/50 ...
- Protection class: IP20- Type 2 according to EN 61643-31:2019- With visual indicator- Pluggable version- Response time: < 25 ns- For snapping onto the 35 mm busbar system- Protection level (8/20 µs): 1900 V/AC- Highest continuous voltage: 600 V/DC- Nominal-/limit-leakage current [L-N]/[N-PE]: 20/4 ...
- Protection class: IP20- Type 2 according to EN 61643-31:2019- With visual indicator- Pluggable version- Response time: < 25 ns- For snapping onto the 35 mm busbar system- Protection level (8/20 µs): 500 V/AC- Highest continuous voltage: 125 V/DC- Nominal-/limit-leakage current [L-N]/[N-PE]: 20/50 ...
- Protection class: IP20- Type 2 according to EN 61643-31:2019- With visual indicator- Pluggable version- Response time: < 25 ns- For snapping onto the 35 mm busbar system- Protection level (8/20 µs): 900 V/AC- Highest continuous voltage: 250 V/DC- Nominal-/limit-leakage current [L-N]/[N-PE]: 20/50 ...
- Protection class: IP20- Type 2 according to EN 61643-31:2019- With visual indicator- Pluggable version- Response time: < 25 ns- For snapping onto the 35 mm busbar system- Protection level (8/20 µs): 1900 V/AC- Highest continuous voltage: 600 V/DC- Nominal-/limit-leakage current [L-N]/[N-PE]: 20/4 ...
- Protection class: IP20- Type 2 according to EN 61643-31:2019- With visual indicator- Pluggable version- Response time: < 25 ns- For snapping onto the 35 mm busbar system- Protection level (8/20 µs): 1000 V/AC- Highest continuous voltage: 250 V/DC- Nominal-/limit-leakage current [L-N]/[N-PE]: 20/5 ...
- Protection type: IP20
- Model 2 according to EN 61643-31:2019
- With optical display
- For freely movable use or fixed laying in photovoltaic systems
- Indoors, outdoors, in areas at risk from explosions, in industry and agriculture, direct laying in the ground
- Flame retardant: VDE 0482 Part 332-1-2; DIN EN/IEC 60332-1-2
- Protection type: IP24
- Heat output max.: 550 W
- Nominal pressure: 7 bar
- Protection type: IP20
- Input voltage: 240 V
- Dimensions of power supply unit (L x W x H): 1100 x 50 x 50 mm
- Cross-section: 6 mm²
- 2 x high-quality Photovoltaics cable
- Protection class: IP67 when plugged in
- Suitable for Connection cables with a cross-section of 4-6 mm²
- Junction sockets for parallel connection of several solar modules
- Dimensions: 10.3 x 38 mm- Voltage: DC 1000 V- PU = 10 pieces ...
- Connection box: IP67 with Schottky bypass diode
- Connection cable: 2 x 1300 mm, 4 mm², MC4
- Cell material: monocrystalline
- Protection class: IP65
- Number of MPP trackers: 1
- Strings per MPP tracker: 1
- Protection class: IP65
- Number of MPP trackers: 2 (from 25KW 3MPP tracker)
- Strings per MPP tracker: 1
- Scope of delivery:
- 1 set of cabling +, -, control and earthing cable (approx. 1.2 m)
- Protection class: IP65
- Number of MPP trackers: 2
- Strings per MPP tracker:
- SH5- 8: 1/1
- SH10: 1/2
- Protection class: IP65
- Number of MPP trackers: 2
- Strings per MPP tracker:
- SG5:1/1
- SG8 - 12: 2/1
- Dimensions (H x W x D): 225 x 625 x 330 mm
- Weight: 15 kg
- Communication connections: CAN bus
- Protection type plugged in: IP68 (1 m, 24 h)
- Voltage max.: 1000 - 1500 V
- Ambient temperature range: *-40 - +11Ω°C
- Protection class plugged in: IP68 (1 m, 24 h)/IP65
- Protection class unplugged: IP2X
- Max. voltage: 1500V (TÜV IEC62852 and UL 6703)
- Protection type plugged in: IP68 (1 m, 24 h)/IP65
- Protection type unplugged: IP2X
- Voltage max.: 1500 V (TÜV IEC62852 and UL 6703)
- For tightening and loosening the cable screw connection (PV4-S) and releasing the locking device on the plug connection
- For contact positioning and clean crimping of the SOLARLOK 2.0 plugs