Sockets, cast resin, wall ducts

30 / 30
New
Hauptbild
Multiple variants
Sealing star for cable protection tube sealing
Immediately available
  • Use with concrete, plastic, steel pipe systems
  • Suitable for RDSS cable protection pipe seal
  • Sealed cables: up to 4 with 1 RDSS clamp, up to 7 with 2 RDSS clamps
Hauptbild
Multiple variants
Double sealing pack, adjustable length for setting in concrete
Only a few items left in stock
  • Type: HSI 150-K2-Varia
  • For waterproof concrete of stress classes 1 and 2
  • Stepless adjustment to the desired wall thickness on site
Hauptbild
Multiple variants
Replacement shrink sleeves
Immediately available
Hauptbild
Multiple variants
Repair sleeves
Delivery item
Hauptbild
Multiple variants
Split system cover for retrospective sealing
Immediately available
  • Suitable for: HSI 150-K2-Varia
  • Split design for sealing newly or already laid cables
  • Super segment ring technology for customised adaptation on site
Hauptbild
Multiple variants
Corrugated pipe seal for corrugated cable protection and media pipes
Immediately available
  • Suitable for: HSI 150-K2-Varia
  • For accumulating seepage water, pressurised water, waterproof concrete of stress class 1
  • The isoring is used to centre the corrugated pipe on the inside of the building and ensures a clean wall finish
Hauptbild
Multiple variants
Standard ring chamber seal
Immediately available
  • With super segment ring technology and plastic press plates
  • For waterproof concrete of stress classes 1 and 2
  • Super segment ring technology for customised adaptation on site
Hauptbild
Multiple variants
Standard ring chamber seal
Immediately available
  • With segment ring technology
  • For waterproof concrete of stress classes 1 and 2
  • Uncovered openings blind sealed ex works
Hauptbild
Multiple variants
Cable protection tube sealing
Only a few items left in stock
  • Waterproof sealing of energy cables in plastic, metal and cement pipes, as well as core holes. A round, smooth, inner surface
    is required. For application in installation pipes, compressive strength of at least 3 bar must be observed
  • The RDSS system consists of a flexible plastic laminate pouch, which is coated on both sides with strips of sealing compound. After coating the sealing compound strips with glide agents, the Rayflate sealing element is simply wound round the cable and pushed into the pipe or the core hole
  • Where three or more cables are installed, RDSS Clips must be used in combination with the RDSS sealing element. Dismantling by draining the filling gas easy and reusable without damaging the cables
Hauptbild
62 010 84
F-Tronic nailing strap for flush-mounted socket PU: 50 pieces
Immediately available
  • For mounting on lever and flush-mounted device plug (order no.: 62 010 74 and 62 010 75)
  • Material: PS
  • Colour: Red
Hauptbild
62 065 22
Plastic flange for D-core drill: 150mm LxW: 235x235mm
Only a few items left in stock
  • Suitable for HSI150 system cover
  • For waterproof concrete of stress classes 1 and 2
  • Connection option for system sealing (e.g. cable conduit connection or cable conduits)
Hauptbild
62 065 40
Hinged face spanner for fitting and removing the system cover
Currently not in stock
  • Ref. no.: 0352010100
Hauptbild
62 065 41
Heat-shrink system cover for cable entry 150mm 3x thermo sleeves: 22-56mm
Delivery item
  • Suitable for: HSI 150-K2-Varia
  • Wide range of applications
  • Easy assembly with bayonet system
Hauptbild
62 065 42
Heat-shrink system cover for cable entry 150mm 7x thermo sleeves: 12-31mm
Immediately available
  • Suitable for: HSI 150-K2-Varia
  • Wide range of applications
  • Easy assembly with bayonet system
Hauptbild
62 065 50
Sealing cover for unused sealing packs for cable entry 150mm
Only a few items left in stock
  • Transparent sealing cover with TPE seal
  • Standing water is easily visible
  • Integrated predetermined breaking point for connecting a drain tap
Hauptbild
62 065 51
Sealing plug for heat-shrink system cover nozzle D: 58mm
Delivery item
  • Suitable for HSI 150-D3/58
  • Ref. no.: 3030300267
Hauptbild
62 065 52
Sealing plug for heat-shrink system cover nozzle D: 32-33mm
Immediately available
  • Suitable for HSI 150-D7/33
  • Ref. no.: 3030300266
Hauptbild
62 092 53
Gel connection joint Raychem GelBox 25-5/25
Currently not in stock
  • Up to 0.6/1 kV
  • Multi-core cable from 3 x 6 mm2 - 5 x 25 mm2
  • Cable cross section: from 5 x 10 mm2 to 5 x 25 mm2
Hauptbild
62 093 61
Compressed gas capsules E7512-0160
Immediately available
  • With CO2 filling
  • Sufficient for up to 3 fillings for a RDSS-100 sleeve
  • Contents: 16 g
Hauptbild
62 121 39
Lubricant for RDSS, E4540-1435/2(B48) lubricant
Immediately available
  • Applied by sponge on the sealing strips of the RDSS sleeve and/or the clip
Hauptbild
62 173 02
WAGO® cable repair set 207-5465/316-000, 11-piece
Immediately available
  • For sheathed cables ø 8-24 mm
  • Not suitable for use under water or in the ground, as there is no longitudinal watertightness
  • Contents:
    - 1 x heat-shrink tubing, diameter 24 mm, shrink factor 4:1, 160 mm long, black
    - 10 x 2773-2401 through connectors, for solid and stranded Ladders
Hauptbild
Multiple variants
Gel connection and junction sleeves
Immediately available
  • Up to 0.6/1 kV
  • For connecting and branching plastic cables
  • Single-core cable from 1 x 10 to 1 x 50 mm2
Hauptbild
Multiple variants
Cast resin connection sleeves
Immediately available
  • For connecting unshielded plastic cables and pipes (e.g. N(A)YY, NYM)
  • Housing: polycarbonate, shock-proof, transparent, snap-on technology
  • No connector
Hauptbild
Multiple variants
RAPID4300B cast resin grouting compound
Immediately available
  • Two-component polyurethane-based cast resin (water-repellent)
  • Workable for approx. 15 minutes
  • System-tested pursuant to CENECEC EN 50393
Hauptbild
Multiple variants
GUROFLEX cast resin grouting compound
Immediately available
  • Two-component cold casting compound based on hydrocarbon resin
  • Up to 0.6/1 kV
  • Workable for approx. 10 minutes
Hauptbild
Multiple variants
Connection sleeves - without connectors
Immediately available
  • UV-resistant and halogen-free
  • For connecting unshielded plastic cables (e.g. N(A)YY, N(A)2XY, N2XH)
  • Heat-shrinkable, cross-linked polyolefin hoses, inside coated with hot-melt adhesive
Hauptbild
Multiple variants
Connection sleeves – with shear head screw connectors
Immediately available
  • UV-resistant and halogen-free
  • For connecting unshielded plastic cables (e.g. N(A)VY, N(A)2XY, N2XH)
  • Heat-shrinkable, cross-linked polyolefin hoses, inside coated with hot-melt adhesive
Hauptbild
Multiple variants
Repair sleeves
Immediately available
  • Up to 0.6/1 kV
  • UV-resistant
  • Slit lengthwise
Hauptbild
Multiple variants
Wall guide
Immediately available
  • Thanks to outer and inner coating, gas and watertight seal between wall entry and masonry, as well as between cable and wall entry
  • Heat-shrinkable, cross-linked polyolefin wall entry, inside coated with hot-melt adhesive
Hauptbild
Multiple variants
Sealing sleeve
Only a few items left in stock
  • Waterproof sealing of energy cables in plastic, metal and cement pipes, as well as core holes. A round, smooth, inner surface is required. For application in installation pipes, compressive strength of at least 3 bar must be observed
  • The RDSS system consists of a flexible plastic laminate pouch, which is coated on both sides with strips of sealing compound. After coating the sealing compound strips with glide agents, the Rayflate sealing element is simply wound round the cable and pushed into the pipe or the core hole
  • Where three or more cables are installed RDSS Clips must be used in combination with the RDSS sealing element