Atmos

24 / 91
Hauptbild
Multiple variants
Replacement thermostat inserts
Immediately available
  • Suitable for Laddomat 21, 21-100, 21-30 and 21-60
Hauptbild
90 011 98
Laddomat replacement pump Wilo Para 25/6 suitable for Ladomat 21+ 21/100
Immediately available
  • Suitable for Laddomat 21 and 21-100
  • Replaces Wilo RS 25/6-3
Hauptbild
90 827 43
Fan motor UCJ 4C52 without Capacitors suitable for all vacuum fans except DC75SE
Immediately available
Hauptbild
Multiple variants
Wood gasification boiler Atmos, model DC GSE
Immediately available
  • Durable with combustion chamber made of patented protective ceramics
  • High efficiency with efficient flue gas removal
  • Vacuum fan with low temperature carbonisation gas extraction
Hauptbild
90 889 22
Replacement pump Laddomat Grundfos UPM3L Flex suitable for Laddomat 21-30, 21-60
Currently not in stock
  • Suitable for Laddomat 21-30 and 21-60
  • Replaces Grundfos LM4, LM6 and LM6A
Hauptbild
90 827 47
Capacitor 1mF - for fan motor UCJ4C52 for all vacuum fan boilers except DC75SE
Immediately available
Hauptbild
90 827 48
Door seal 18x18mm for all GS/GSE boilers
Immediately available
Hauptbild
90 828 57
Flue gas thermostat up to 300¦C for GSE boiler
Immediately available
  • Suitable for Sieger: DC 20/25/32/40 GS, DC 30/40/50/75 SE, FBV 22/25/40/50
  • Up to 300°C
  • Ref. no.: 54915202
Hauptbild
90 827 45
Fan seal Klingerit Grey-red
Immediately available
  • Suitable for Sieger: D20P, DC20/25/32/40 GS, DC 30/40/50/75 SE, FBV 22/25/31/40/50
  • grey/red
  • Ref. no.: 54915216
Hauptbild
Multiple variants
Pellet hose between burner and screw conveyor
Immediately available
  • Length: 1 m
Hauptbild
Multiple variants
Wood gasification boiler DC GSE with automatic ignition and ACD 04
Delivery item
- With automatic ignition
- With ACD04 touch control for boiler and ignition control as well as operation of up to 3 mixed heating circuits
- Durable thanks to Burning chambers made of patented protective ceramic
- High efficiency due to efficient flue gas discharge
- Vacuum fan with carbonisation gas extraction
- Separate adjustment of primary and secondary air
- Limitation of the maximum flue gas temperature via a Belimo servomotor
- Large filling door 450 x 260 mm

Type

DC GSE

18

25

30

EEK space heating

A+++ to D

A+

A+

A+

Nominal load

[kW]

19

25

29.8

Regulated chimney draught

[Pa]

16

18

20

Efficiency

[%]

90.3

90.5

90.8

Firewood length max.

[mm]

330

530

530

Return temperature min.

[°C]

65

65

65

Exhaust pipe connection

[mm]

150

150

150

Dimensions (W x H x D)

[mm]

680 x 1281 x 820

680 x 1281 x 1020

680 x 1281 x 1020

Weight

[kg]

376

469

466

Hauptbild
90 835 52
Atmos impeller Ø 150 mm
Immediately available
Hauptbild
Multiple variants
Pellet boiler set P21
Immediately available
  • Pellet burner A25 (can be mounted left or right)
  • Screw conveyor included (length: 1.2/2.0/2.5 m)
  • Recommended pellets 6-8 mm long; calorific value 15-18 MJ/kg
Hauptbild
Multiple variants
Wood gasification boiler Atmos DC
Delivery item
- With automatic ignition
- Compact assembly F8
- With Compact assembly F8 consisting of mixed pump groups for return flow boost and heating circuit integration as well as a boiler safety group
- With ACD04 touch control for boiler and ignition control as well as the operation of up to 3 mixed heating circuits
- Durable due to Burning chambers made of patented protective ceramic
- High efficiency due to efficient flue gas discharge
- Vacuum fan with carbonisation gas extraction
- Separate adjustment of primary and secondary air
- Limitation of the maximum flue gas temperature via a Belimo servomotor
- Large filling door 450 x 260 mm

Type

DC GSE

22

EEK space heating

A+++ to D

A+

Nominal load

[kW]

23

Regulated chimney flue

[Pa]

18

Efficiency

[%]

91.8

Firewood length max.

[mm]

380

Return temperature min.

[°C]

65

Exhaust pipe connection

[mm]

150

Dimensions (W x H x D)

[mm]

680 x 1281 x 820

Weight

[kg]

373

Hauptbild
90 822 08
Commissioned by the manufacturer.
Delivery item

Austria on request!You can find the Atmos commissioning order as a download PDF in our online shop www.weinmann-schanz.de under the path: "Heating - Heat generators, tanks - Solid fuel boilers - Commissioning Atmos" or enter the order no. in the search field. ...

Hauptbild
Multiple variants
Wood gasification boiler GSX 50
Currently not in stock
  • Large capacity of up to 210 litres and 580 mm depth
  • Large filling door 450 x 310 mm
  • Durable with combustion chamber made of patented protective ceramics
Hauptbild
90 835 24
Sibral tape for sealing combustion chamber
Immediately available
  • Suitable for Sieger: DC 20/25/32/40 GS, DC 30/40/50/75 SE, FBV 22/25/31/40/50
  • For sealing between spherical chambers and nozzle
  • Ref. no.: 54915218
Hauptbild
90 827 44
Impeller Ø 175 mm
Immediately available
Hauptbild
90 835 47
Atmos STB safety temperature limiter 110¦C from serial number 168800
Immediately available
Hauptbild
90 835 44
Atmos thermometer in boiler control panel
Immediately available
Hauptbild
90 827 52
On/off switch for Atmos-GSE
Immediately available
Hauptbild
90 835 79
Wood gasification boiler system DC30GSE
Replacement item available
  • Set consisting of:
    1 x Atmos DC 30 GSE Wood gasification boiler (90 620 86)
  • Output 29.8 kW
    1 x Thermal cut-out (90 029 01)
    1 x Boiler safety group with safety valve (90 018 02)
  • 3 bar
Hauptbild
Multiple variants
Hopper seal set (item no. 26)
Immediately available
Hauptbild
90 835 38
Belimo actuator
Currently not in stock