Atmos

24 / 88 Atmos
Hauptbild
90 011 98
Laddomat replacement pump Wilo Para 25/6 suitable for Ladomat 21+ 21/100
Immediately available
  • Suitable for Laddomat 21 and 21-100
  • Replaces Wilo RS 25/6-3
Hauptbild
Multiple variants
Wood gasification boiler Atmos, model DC GSE
Immediately available
  • Durable with combustion chamber made of patented protective ceramics
  • High efficiency with efficient flue gas removal
  • Vacuum fan with low temperature carbonisation gas extraction
Hauptbild
Multiple variants
Pellet boiler set P21
Immediately available
  • Pellet burner A25 (can be mounted left or right)
  • Screw conveyor included (length: 1.2/2.0/2.5 m)
  • Recommended pellets 6-8 mm long; calorific value 15-18 MJ/kg
Hauptbild
90 827 45
Fan seal Klingerit Grey-red
Immediately available
  • Suitable for Sieger: D20P, DC20/25/32/40 GS, DC 30/40/50/75 SE, FBV 22/25/31/40/50
  • grey/red
  • Ref. no.: 54915216
Hauptbild
Multiple variants
Wood gasification boiler Atmos DC
Delivery item
- With automatic ignition
- Compact assembly F8
- With Compact assembly F8 consisting of mixed pump groups for return flow boost and heating circuit integration as well as a boiler safety group
- With ACD04 touch control for boiler and ignition control as well as the operation of up to 3 mixed heating circuits
- Durable due to Burning chambers made of patented protective ceramic
- High efficiency due to efficient flue gas discharge
- Vacuum fan with carbonisation gas extraction
- Separate adjustment of primary and secondary air
- Limitation of the maximum flue gas temperature via a Belimo servomotor
- Large filling door 450 x 260 mm




Type




DC GSE




22






EEK space heating




A+++ to D




A+






Nominal load




[kW]




23






Regulated chimney flue




[Pa]




18






Efficiency




[%]




91.8






Firewood length max.




[mm]




380






Return temperature min.




[°C]




65






Exhaust pipe connection




[mm]




150






Dimensions (W x H x D)




[mm]




680 x 1281 x 820






Weight




[kg]




373





Hauptbild
90 828 57
Flue gas thermostat up to 300¦C for GSE boiler
Immediately available
  • Suitable for Sieger: DC 20/25/32/40 GS, DC 30/40/50/75 SE, FBV 22/25/40/50
  • Up to 300°C
  • Ref. no.: 54915202
Hauptbild
90 102 96
Ignition chamber fixing plate of the DC GSE glow coil
Only a few items left in stock
  • Suitable for DC GSE glow plug
  • Ref. no.: 709.153.8
Hauptbild
90 102 92
Ignition chamber retaining plate glow plug DC GSE for car ignition
Only a few items left in stock
  • Suitable for glow plug auto ignition DC GSE
  • Ref. no.: 709.149.3
Hauptbild
90 102 95
Ignition chamber cable glow coil for car ignition DC GSE
Only a few items left in stock
  • Suitable for DC GSE glow plug
  • Ref. no. 709.146.3
Hauptbild
90 835 57
Atmos heating flap complete
Immediately available
Hauptbild
90 857 98
Limit switch for burner for Atmos burner A25/A45
Currently not in stock
Hauptbild
Multiple variants
Nozzle incl. sealing cord and putty (item no. 27)
Immediately available
Hauptbild
90 102 98
Ignition chamber dummy basket for car ignition DC GSE
Only a few items left in stock
  • For the DC GSE car ignition
  • Ref. no.: 709.149.5
Hauptbild
90 835 60
Atmos plastic protection for fresh air supply flap
Currently not in stock
Hauptbild
90 835 67
Atmos plastic crown nut M8
Immediately available
Hauptbild
Multiple variants
Combustion chamber left + right (item no. 33)
Immediately available
Hauptbild
Multiple variants
Seal for cast iron valve (item no. 12)
Immediately available
Hauptbild
Multiple variants
Hopper side wall (item no. 28)
Immediately available
Hauptbild
Multiple variants
Replacement thermostat inserts
Immediately available
  • Suitable for Laddomat 21, 21-100, 21-30 and 21-60
Hauptbild
Multiple variants
Wood gasification boiler GSX 50
Currently not in stock
  • Large capacity of up to 210 litres and 580 mm depth
  • Large filling door 450 x 310 mm
  • Durable with combustion chamber made of patented protective ceramics
Hauptbild
Multiple variants
Hopper seal set (item no. 26)
Immediately available
Hauptbild
Multiple variants
Wood gasification boiler DC GSE with automatic ignition and ACD 04
Delivery item
- With automatic ignition
- With ACD04 touch control for boiler and ignition control as well as operation of up to 3 mixed heating circuits
- Durable thanks to Burning chambers made of patented protective ceramic
- High efficiency due to efficient flue gas discharge
- Vacuum fan with carbonisation gas extraction
- Separate adjustment of primary and secondary air
- Limitation of the maximum flue gas temperature via a Belimo servomotor
- Large filling door 450 x 260 mm




Type




DC GSE




18




25




30






EEK space heating




A+++ to D




A+




A+




A+






Nominal load




[kW]




19




25




29.8






Regulated chimney draught




[Pa]




16




18




20






Efficiency




[%]




90.3




90.5




90.8






Firewood length max.




[mm]




330




530




530






Return temperature min.




[°C]




65




65




65






Exhaust pipe connection




[mm]




150




150




150






Dimensions (W x H x D)




[mm]




680 x 1281 x 820




680 x 1281 x 1020




680 x 1281 x 1020






Weight




[kg]




376




469




466





Hauptbild
Multiple variants
Ash box (item no. 36)
Currently not in stock
Hauptbild
Multiple variants
Exhaust brake (item no. 31)
Immediately available

PU = 1 x “left” design, 1 x “right” design ...