BENNING
- Simple and safe contacting without opening the CEE sockets
- Coloured measuring sockets with clear conductor assignment
- Universal application with 4 mm safety measuring sockets
- 3-phase
- 5-pin
- Conductors fed in individually with double insulation
- Suitable for Benning voltage tester order no.: 70 128 34, 70 128 35, 70 128 36, 70 130 22
- Protection class: IP40
- Detection: Red LED and buzzer
- Measurement category: CAT IV 600 V, CAT III 1000 V
- For the installation and periodic testing of grid-connected PV systems in accordance with VDE 0126-23 (DIN EN 62446)
- Protective conductor resistance measurement (test current 200 mA DC)
- Open-circuit voltage measurement with polarity test up to 1000 V DC
- For testing electrical and medical electrical devices
- Testing under DGUV regulation 3, BetrSichV in accordance with:
- DIN VDE 0701-0702: 2008: For electrical devices (ÖVE/ÖNORM E 8701, NEV, NEN 3140)
- DIN EN 62353: For electrical medical devices (VDE 0751-1:2015, ÖVE/ÖNORM E 8751-1)
- DIN EN 60974-4: For welding devices (only ST 760) (VDE 0544-4:2017, ÖVE/ÖNORM EN 60974-4) - Can be saved in full on SD card
- For checking that protective contact sockets are properly connected
- Wiring errors such as missing PE, N und L conductors, mixing up L and PE conductors are displayed via three LEDs
- Voltage: 230 V
- Suitable for all BENNING multimeters with rubber protective frame for securely fastening the multimeter to switch cabinets, distribution boxes, pipes, walls, machine and system parts
- Scope of delivery:
- Strong magnetic holder
- Adapter
- Strap
- Display: LCD illuminated
- Display range: 6000
- Basic accuracy: 0.20%
- The coding for charging cables is simulated using a rotary selector switch:
- No cable: ∞ Ω
- 13 A cable: 1500 Ω
- 20 A cable: 680 Ω
- 32 A cable: 220 Ω
- 64 A cable: 100 Ω - Input voltage:
- 1-phase: up to 250 V, 50 Hz - 60 Hz
- 3-phase: up to 430 V, 50 Hz - 60 Hz - Maximum test current: 40 A (10 ms) periodic operation
- Suitable for: Benning MM 10-PV, Benning CM 10-PV
- Display: LCD
- Display range: 2000
- Basic accuracy: 0.50%
- Protection class: IP65
- Display: optical, LED/LCD (bel.)
- Voltage range AC: 1 V-1000 V
- Display: LCD illuminated
- Display range: 6000
- Basic accuracy: 0.20%
- Irradiation and temperature measuring device ideal for planning, commissioning and periodic testing of grid-connected PV systems in accordance with VDE 0126-23 (DIN EN 62446) and testing thermal solar systems (solar thermal)
- Measurements: Solar irradiation (irradiance), Temperature (module/environment), digital compass (compass direction), inclinometer (roof/module inclination)
- Calibrated Photovoltaics for reference parts for precise measurement of solar irradiance
- ø 4 mm
- Made of silicone
- Red, black
- Display: LCD
- Display range: 6000
- Voltage range AC: No
- Safety testing of electrical appliances/work equipment, e.g. Mechanics Tools, power tools, Lights, extension leads, HV appliances, in accordance with VDE 0701-0702, BGV A3
- Automatic test sequence for class I, II (III) devices, extension/device connection cables with IEC plugs
- Protective conductor resistance (200 mA test current)
- Protection class: IP53
- Detection: Red LED and buzzer
- Measurement category: CAT IV 600 V, CAT III 1000 V
- Protection class: IP54
- Display: LED
- Voltage range AC: 12 V - 690 V
- Safety measuring leads: ø 4 mm
- 2-piece, red/black
- Length: 1.40 m, with 2 mm measuring tip
- Protection class: -
- Display: LCD
- Display range: 5000