BENNING
- 3-phase
- 5-pin
- Conductors fed in individually with double insulation
- Protection class: IP30
- Display: LCD illuminated
- Display range: 6000
- Display: LCD
- Display range: 6000
- Voltage range AC: No
- Protection class: -
- Display: LCD
- Display range: 4000
- For active and passive testing of 1- and 3-phase equipment up to 32A
- Test according to IN VDE 0701-0702, DIN EN 62353, DIN EN 60974-4 and DGUV V3
- Testing of equipment with CEE connection, 1-phase (230 V, 16 A) and 3-phase (400 V, 16 + 32 A)
- Display: LCD illuminated
- Display range: 6000
- Basic accuracy: 0.20%
- Display: LCD
- Display range: 2000
- Basic accuracy: 0.50%
- Protection type: IP65
- Display: LED
- Voltage range AC: 12 V - 1000 V
- Safety measuring leads: ø 4 mm
- 2-piece, red/black
- Length: 1.40 m, with 2 mm measuring tip
- Suitable for photovoltaic measuring device PU 1-1
- Protection class: IP54
- Display: LED
- Voltage range AC: 12 V - 690 V
- Protection class: IP30
- Display: LCD
- Display range: 1999
- Application:
As part of the commissioning and periodic testing of grid-connected Photovoltaics systems in accordance with VDE 0126-23 (DIN EN 62446), polarity tests, open-circuit voltages and short-circuit current measurements of parallel-connected PV strings can be carried out, stored and documented safely and efficiently up to 1500 V/40 A. - General measurement functions:
- Polarity test of the PV generator/PV cabling
- Open-circuit voltage measurement for modern 1500 V DC systems
- Short-circuit current measurement on PV strings up to 40 A DC
- Solar irradiation (W/m²) and PV module/ambient temperature (°C) via BENNING SUN 2 (order no.: 70 128 24) - Performance features:
- Automatic test sequence (+/-, Vo/c, ls/c, W/m², °C) with reverse polarity protection
- Powerful short-circuit current measurement, up to 4 x greater reserve than standard PV testers with 10 A limitation
- Reduced testing times and dismantling effort, as PV strings no longer have to be separated individually and tested one after the other
- Reduces the risk of failure due to overload when testing PV strings of unknown power
- Real-time clock with date and time stamp per measurement
- Display: LCD illuminated
- Display range: 6000
- Basic accuracy: 1.00%
- Protection class: -
- Display: LCD
- Display range: 5000
- Protection class: -
- Display: LCD
- Display range: 2000
- Safety testing of electrical appliances/work equipment, e.g. Mechanics Tools, power tools, Lights, extension leads, HV appliances, in accordance with VDE 0701-0702, BGV A3
- Automatic test sequence for class I, II (III) devices, extension/device connection cables with IEC plugs
- Protective conductor resistance (200 mA test current)
- Protection class: IP30
- Display: LCD illuminated
- Display range: 4200
- Safety measuring leads: ø 4 mm
- 2-piece, red/black
- Length: 1.40 m, with 4 mm measuring tip
- Display: LCD illuminated
- Display range: 6000
- Basic accuracy: 0.20%
- Measuring function Specific:
- RLOW measurement with 200 mA DC test current and automatic polarity reversal / PE resistance measurement under mains voltage (3-wire method)
- Insulation resistance with test voltage of 50 V - 1000 V DC / RISO ALL, auto-test between all Ladders (L-N, L-PE and N-PE), RISO pre-test, protects connected devices from test damage
- For testing high and low-ohm resistances
- Continuity and diode test via LEDs and testing number
- Display via 3 LEDs: 0-100 Ω/1 kΩ/10 kΩ
- For testing electrical devices, medical electrical devices
- Testing within the frames of the DGUV regulation, BetrSichV acc:
- DIN EN 50678 (VDE 0701)
- DIN EN 505699 (VDE 0702)
- DIN 62353 (VDE 0751-1) - Completely storable from SD card