BENNING
- Protection type: IP65
- Display: LED
- Voltage range AC: 12 V - 1000 V
- Protection class: IP65
- Display: optical, LED/LCD (bel.)
- Voltage range AC: 1 V-1000 V
- Protection class: IP65
- Display: LED
- Voltage range AC: 12 V - 1000 V
- Protection class: -
- Display: LCD
- Display range: 5000
- Display: LCD illuminated
- Display range: 6000
- Basic accuracy: 0.20%
- Protection class: IP30
- Display: LCD illuminated
- Display range: 6000
- Application:
- For electrical engineering, industry, photovoltaics
- Testing of electrical systems in accordance with VDE 0100/0105 and IEC 60364
- Display: LCD
- Display range: 2000
- Basic accuracy: 0.50%
- Display: 9999 digit (illuminated)
- Insulation resistance: 300 kΩ - 20 GΩ
- Low ohmic resistance: 0.01 Ω - 60 Ω
- Suitable for Benning voltage tester order no.: 70 128 34, 70 128 35, 70 128 36, 70 130 22
- Suitable for: Benning MM 10-PV, Benning CM 10-PV
- Protection class: IP40
- Detection: Red LED and buzzer
- Measurement category: CAT IV 600 V, CAT III 1000 V
- Display: LCD illuminated
- Display range: 6000
- Basic accuracy: 0.20%
- Safety measuring leads: ø 4 mm
- 2-piece, red/black
- Length: 1.40 m, with 2 mm measuring tip
- Protection class: IP54
- Display: LED
- Voltage range AC: 12 V - 690 V
- Display: LCD illuminated
- Display range: 6000 with bar graph
- Basic accuracy: 0.50%
- Application:
- For electrical engineering, industry, photovoltaics
- Testing of electrical systems in accordance with VDE 0100/0105 and IEC 60364
- Protection class: -
- Display: LCD
- Display range: 2000
- Irradiation and temperature measuring device ideal for planning, commissioning and periodic testing of grid-connected PV systems in accordance with VDE 0126-23 (DIN EN 62446) and testing thermal solar systems (solar thermal)
- Measurements: Solar irradiation (irradiance), Temperature (module/environment), digital compass (compass direction), inclinometer (roof/module inclination)
- Calibrated Photovoltaics for reference parts for precise measurement of solar irradiance
- For the installation and periodic testing of grid-connected PV systems in accordance with VDE 0126-23 (DIN EN 62446)
- Protective conductor resistance measurement (test current 200 mA DC)
- Open-circuit voltage measurement with polarity test up to 1000 V DC
- 3-phase
- 5-pin
- Conductors fed in individually with double insulation
- Simple and safe contacting without opening the CEE sockets
- Coloured measuring sockets with clear conductor assignment
- Universal application with 4 mm safety measuring sockets
- Display range: 9,999
- Basic accuracy: 1%
- AC current: 0.3 A - 35 A