BENNING
- Protection type: IP65
- Display: LED
- Voltage range AC: 12 V - 1000 V
- Protection class: IP65
- Display: LED
- Voltage range AC: 12 V - 1000 V
- Protection class: IP65
- Display: optical, LED/LCD (bel.)
- Voltage range AC: 1 V-1000 V
- Display: LCD
- Display range: 2000
- Basic accuracy: 0.50%
- Display: LCD illuminated
- Display range: 6000
- Basic accuracy: 0.20%
- Protection class: -
- Display: LCD
- Display range: 5000
- Protection class: IP40
- Detection: Red LED and buzzer
- Measurement category: CAT IV 600 V, CAT III 1000 V
- For testing electrical devices, medical electrical devices
- Testing within the frames of the DGUV regulation, BetrSichV acc:
- DIN EN 50678 (VDE 0701)
- DIN EN 505699 (VDE 0702)
- DIN 62353 (VDE 0751-1) - Completely storable from SD card
- Protection class: -
- Display: LCD
- Display range: 2000
- Protection class: IP30
- Display: LCD illuminated
- Display range: 6000
- Protection class: IP53
- LED Torches with On-off switch: Yes
- Detection: Red LED and buzzer
- Display: LCD illuminated
- Display range: 6000
- Basic accuracy: 0.20%
- Application:
- For electrical engineering, industry, photovoltaics
- Testing of electrical systems in accordance with VDE 0100/0105 and IEC 60364
- Display: LCD
- Display range: 2000
- Voltage range AC: No
- For the installation and periodic testing of grid-connected PV systems in accordance with VDE 0126-23 (DIN EN 62446)
- Protective conductor resistance measurement (test current 200 mA DC)
- Open-circuit voltage measurement with polarity test up to 1000 V DC
- Suitable for Benning voltage tester order no.: 70 128 34, 70 128 35, 70 128 36, 70 130 22
- Safety measuring leads: ø 4 mm
- 2-piece, red/black
- Length: 1.40 m, with 2 mm measuring tip
- Display range: 60,000 (Lighting) with bar graph
- Basic accuracy: 0.03%
- Voltage AC: 10 µV - 1000 V
- Display: LCD
- Display range: 2000
- Voltage range AC: 100 µV - 750 V
- Display: LCD illuminated
- Display range: 6000
- Basic accuracy: 0.20%
- Protection class: IP53
- Detection: Red LED and buzzer
- Measurement category: CAT IV 600 V, CAT III 1000 V
- Display: LCD illuminated
- Display range: 6000 with bar graph
- Basic accuracy: 0.50%
- Measuring function Specific:
- RLOW measurement with 200 mA DC test current and automatic polarity reversal / PE resistance measurement under mains voltage (3-wire method)
- Insulation resistance with test voltage of 50 V - 1000 V DC / RISO ALL, auto-test between all Ladders (L-N, L-PE and N-PE), RISO pre-test, protects connected devices from test damage