Brigon
- Suitable for checking ionisation electrodes- Display: LCD illuminated- Non-contact voltage detection- Voltage range AC: 0.01 mV - 600 V- DC voltage range: 0.01 mV - 1000 V- Current measuring range AC: 0.1 μA - 20 A- DC current measuring range: 0.1 μA - 20 A- Resistance measuring range: 0.1 Ω - ...
- Suitable for filter paper strips and round blanks:
- Incl. soot pattern comparison scale, filter paper strips, lubricating grease
- for differential pressure measurements and measuring tasks up to ± 200.00 mbar, e.g. on gas boilers- Display of differential pressure in mbar, bar, Pa, hPa, psi, ozin2, inHg, mmHg, kgcm2, inH2O, ftH2O, cmH2O- Scope of delivery: - Battery: 9 V (order no.: 62 079 50) - Belt pouch - Silicone tube ...
- For emission measurement at combustion plants (GAS/oil/solid fuels)
- For fuels: oil, gas and solid fuels
- Basic functions: flue gas measurement
- For the early detection of excessive CO concentrations in the ambient air
- For use in boiler rooms, workshops, ductwork...
- Measuring range 0 ... 999 ppm CO
- For measurement openings up to max. 14 mm ø
- Aluminium plate 25 x 25 mm
- With stainless steel spring clip, designed as a handle
- For differential pressure measurements and measuring tasks up to ± 200.00 mbar, e.g. on gas boilers
- Display of the differential pressure in mbar, bar, Pa, 1Pa, psi, ingw, mmwg
- Scope of delivery:
- Pressure gauge incl. Batteries: (3 x Micro AAA)
- Plastic bag
- Silicone hoses 2x 1 m
- For all common refrigerants
- Visual and audible alarm
- Detectable: CFC, HFC, HCFC, R11, R22, R32, R134a, R290, R410, R600, etc...
- For differential pressure measurements and measurement tasks that require complete documentation of the measurement results
- Measuring range: 0..200 mbar
- Resolution: 0.01 mbar
- For detecting natural gas-liquid and hydrogen leaks
- Measuring range: 0 to 9999 ppm / 0 to 2.5 vol.%
- Colour LC display
- Content: 40 units
- For continuous monitoring of the CO2 concentration, humidity and indoor temperature in e.g. schools, offices, public buildings, production facilities, storage rooms, laboratories, etc.
- Acoustic and optical alarm
- CO2/RH/temperature recording
- Suitable for Brigon 500NT/520/530/550/560
- PU = 5 pieces
- Suitable for Brigon exhaust gas detectors
- Model Bird 2
- Incl. batteries, power pack/charger and thermal paper
- Completely filled with CO2 fluid
- 1 bottle of replacement fluid
- Suction device
- Shows the material moisture in wood quickly and reliably
- Function test
- Measuring range: 6-99.9%
- For emission measurement on incinerators (GAS/OIL/solid fuels)
- For fuels: oil, gas and solid fuels
- Basic functions: waste gas measurement, tension, differential pressure
- Contents: 100 ml
Nickel-plated brass, 7mm fhardened steel 8 mm ID with self lock ...
(8328) fully assembled with:8313, (70 036 15), 8314, (70 036 16) ...
- Contents: 100 ml
- Fully assembled with:
- 8382 (70 036 30),
- 8384 (70 036 32),
- 8385 (70 036 33),
- 8393 (70 036 37),
- 8391 (70 036 36)