- For emission measurement at combustion plants (GAS/oil/solid fuels)
- For fuels: oil, gas and solid fuels
- Basic functions: flue gas measurement
- Suitable for checking ionisation electrodes- Display: LCD illuminated- Non-contact voltage detection- Voltage range AC: 0.01 mV - 600 V- DC voltage range: 0.01 mV - 1000 V- Current measuring range AC: 0.1 μA - 20 A- DC current measuring range: 0.1 μA - 20 A- Resistance measuring range: 0.1 Ω - ...
- For the early detection of excessive CO concentrations in the ambient air
- For use in boiler rooms, workshops, ductwork...
- Measuring range 0 ... 999 ppm CO
- for differential pressure measurements and measuring tasks up to ± 200.00 mbar, e.g. on gas boilers- Display of differential pressure in mbar, bar, Pa, hPa, psi, ozin2, inHg, mmHg, kgcm2, inH2O, ftH2O, cmH2O- Scope of delivery: - Battery: 9 V (order no.: 62 079 50) - Belt pouch - Silicone tube ...
- Suitable for filter paper strips and round blanks:
- Incl. soot pattern comparison scale, filter paper strips, lubricating grease
- For measurement openings up to max. 14 mm ø
- Aluminium plate 25 x 25 mm
- With stainless steel spring clip, designed as a handle
- For differential pressure measurements and measurement tasks that require complete documentation of the measurement results
- Measuring range: 0..200 mbar
- Resolution: 0.01 mbar
- Content: 40 units
- Suitable for Brigon exhaust gas detectors
- Model Bird 2
- Incl. batteries, power pack/charger and thermal paper
- Calculated dew point and wet bulb temperature
- 1-second measurement cycle rate
- MAX-MIN-HOLD function
- With dew point sensor, reacts to escaping exhaust gases
- Acoustic signal (buzzing tone), optical signal (red LED/green LED)
- Flexible swan neck: 300 mm long
- Suitable for Brigon 500NT/520/530/550/560
- PU = 5 pieces
- Measuring scale for building materials and wood
- Automatic switch-off (auto off function)
- Rubberised side edges for safe handling
- For continuous monitoring of the CO2 concentration, humidity and indoor temperature in e.g. schools, offices, public buildings, production facilities, storage rooms, laboratories, etc.
- Acoustic and optical alarm
- CO2/RH/temperature recording
- For emission measurement on incinerators (GAS/OIL/solid fuels)
- For fuels: oil, gas and solid fuels
- Basic functions: waste gas measurement, tension, differential pressure
- Contents: 100 ml
Nickel-plated brass, 7mm fhardened steel 8 mm ID with self lock ...