HT Instruments
- Display: LCD illuminated
- Display range: 4000
- Voltage range AC: 0.1 mV - 600 V
- Digital multimeter HT 211
- Display: LCD illuminated
- Display range: 4000
- Protection class: IP64
- Display: optical, LED/LCD (bel.)
- Voltage range AC: 6 V - 690 V
- Protection class: -
- LED Torches with On/Off switch: Yes
- Detection: Red LED and buzzer
- Display: LCD
- Display range: 4000
- Voltage range AC: 1 mV - 600 V
- Endoscope camera HTB500
- Display type/size (mm/inch): -/3,5"
- Display resolution: 640 x 320 px
- Voltage testers HT10
- Protection class: IP64
- Display: optical, LED/LCD
- Detects all magnetic fields
- Testing of solenoid valves in pneumatic and hydraulic systems
- Protection type: IP 64
- Display: LCD
- Display range: 4000
- Voltage range AC: 1 mV - 600 V
- Detection: LED red/green and buzzer
- Measurement category: CAT IV 1000V
- Voltage range: 100V - 1000 V
- Display: LCD illuminated
- Display range: 4000
- Voltage range AC: 0.1 mV - 600 V
- Protection class: IP64
- Display: optical, LED/LCD
- Voltage range AC: 12 V - 1000 V
- Simulation of states of charge and for testing the effectiveness of protective measures
- 1- and 3-phase test adapter with type 2 plugs (length: 600 mm)
- Combination only possible with HT master models:
- Combi G2 (order no.: 70 005 01)
- Combi G3 (order no.: 70 005 02)
- Localisation of live cables, metals and wooden structures
- Automatic calibration
- LCD display with bar graph
- For connection to Multimeters Mercury
- Flexible True RMSAC current transformer
- Alternating current: 0.1 A-3000 A (TRMS)
- VDE0100 / VDE0105 Installation tester with auto-sequence function
- AUTO sequence (Ra-> RCD-> Riso)
- Low-resistance measurement with >200 mA DC
- For precise measurement of the earthing resistance without the use of auxiliary earth electrodes
- Earthing measurement without auxiliary earth electrodes from 0.010 Ω to 1000 Ω
- Leakage current measurement from 0.05 mA to 20 A/AC
- For testing, risk troubleshooting and acceptance of PV systems in accordance with VDE 0126-23 (EN 62446) up to 1500 V & 40 A DC
- A single keystroke for all commissioning tests
- Testing of mono and bifacial modules
- For Smartphone Android with USB-C
- IR resolution: 120 x 90 pixels
- Power supply via Smartphone
- For all electrical safety tests required under VDE 0126-23 (EN 62446) Part 1, 2, 4 and IEC/EN 62446, VDE 0126-23
- Measurement functions:
- Insulation resistance measurement 250 / 500 / 1000 V DC, 0.019 Ω - 1999 Ω
- Continuity test / low-ohm measurement Rpe 0.00 Ω - 199 Ω
- Neutral voltage measurement Uoc to 1000 V DC
- Short circuit current measurement Isc 0.1 -15 A DC
- Voltage measurement DC, 2.0 - 999V
- Current measurement with current pliers HT4004
- Output measurement 0 - 999 W
- Riso individual measurement + or - to ground - Performance features:
- Automatic test run
- Automatic display of voltage polarity
- Data logger function
- Measurement value storage for 999 measurements
- Measurement interval from 5 sec to 60 min.
- USB interface
- Overvoltage category CAT III 300 V - CAT 1000 V
- VDE0100 / VDE0105 Installation tester with auto-sequence function
- AUTO sequence (Ra-> RCD-> Riso)
- Low-resistance measurement with >200 mA DC
- Measurement medium: air / surface
- Emission factor: 0.1 to 1.0
- Measuring range: -50°C to +380°C
- VDE0100 / VDE0105 installation tester with auto-sequence function, including EVSE test sequence for charging stations
- AUTO sequence (Ra-> RCD-> Riso)
- Low-resistance measurement with >200 mA DC
- Determines the insulation resistance of an individual module, string or even an entire PV field with a test voltage of up to 1,500 V DC in accordance with EN 62446 (VDE0126-23)
- Measurement functions:
- Insulation measurement up to 1,500 V DC also on voltage-carrying systems
- Localisation of the insulation fault in a PV string
- Low ohm measurement (protective conductor) with a test current > 200 mA
- Measurement of polarisation index (PI) & di-electric absorption ration (DAR)
- Measurement of AC voltage parts in PV string - Performance features:
- Output measurement 0 - 999 W
- Riso individual measurement + or - to ground