SPIROTECH
- Removes magnetic and non-magnetic sludge particles from the heating system
- Removable, strong magnet with field enhancement on the external side of the dirt separator
- Can be installed horizontally and vertically
Technical data:
- Suitable for air separator SpiroVent® universal RV2 and dirt separator MB3/ MBL
- Separator not included!
- Continuous and effective microbubble degassing of heating, cooling and process systems
- Leakage-free and easy to install
- Maintenance-free operation
- 1 x magnetite and dirt separator MB3 DN 25 (1“) IT
- Can be installed horizontally and vertically
- Housing material: brass
1 x Microbubble air separator Spirovent RV2 DN 25 (1") IT
- Continuous and effective microbubble degassing of heating, cooling and process systems
- Leakage-free and easy to install
- Maintenance-free operation
- Air in solar fluids
The viscosity of liquids that contain glycol is significantly higher than water. Depending on the concentration of the liquid, air bubbles require several hours to rise to the surface. Air bubbles trapped in the liquid therefore remain in the volume flow and pass through the entire system.
The consequence: problems with circulation, heat transfer and corrosion.
The little air bubbles are forced to rise by the fixed resistors in the spiral pipe. Installation must not be at the highest point but directly on the solar flow pipe.
Temperature: max. 180°C
Operating pressure: max. 10 bar
Housing: brass
”AutoClose”
This design also offers differentiation between air and steam, and automatically closes when the evaporation temperature is reached. Effectively keeps solar systems consistently air-free.
Advantages: - No stagnation caused by steam emission
- No fluid loss
- Suitable for connection sizes: 22 mm, DN 20 (3/4”) to DN 40 (1 1/2”), and vertical: 22 mm and DN 20 (3/4”) to DN 25 (1”)
- Suitable for connection sizes DN 50-65
- Insulating shells made of PUR hard foam
- In accordance with the German Heating System Regulation (HeizAnlV) and Energy Saving Regulation (EnEV)
- For solar systems
- With connection thread on the vent valve for vent pipe
Technical data: - Housing: brass
- Continuous and effective microbubble degassing of heating, cooling and process systems
- Leakage-free and easy to install
- Maintenance-free operation
- DN 15 (1/2") IT
- Leakage-free
- Cannot be shut off
- Can be installed on the SpiroTrap MB3 and SpiroVent RV2 connections for flushing operations
- Using this adapter, cleaning devices such as, for example, flushing compressors or additives can be connected or added
- Can only be used up to size DN 25 or clamp connection
- Advantages of Spirotrap with magnet:
- Outstanding protection of pumps with magnetic rotors and other valuable system components against (magnetic) sludge particles
- Extremely easy to use: The sludge is drained very easily by actuating a draw-off mechanism
- When you buy a SpiroPress® PicoControl Kompact*, Spirotech will take care of the commissioning (worth €430.00) free of charge during the promotional period of 01.09. – 29.10.2020.
- Send the completed form by email to heizungstechnik@weinmann-schanz.de or by fax to 0 74 33. 98 92 92
- The order will be forwarded to Spirotech
- Removes mud particles
- For installation in the return
Technical data: - Housing: brass
- Advantages of Spirotrap:
- Even extremely small particles, from 5 μm (= 0.005 mm), are separated and eliminated
- Rinses sludge particles while the system is running
- A micro air bubble and dirt separator combined with a performance-enhancing external magnet for cooling and hot water systems
- Variable connection that can be rotated 360 degrees for vertical, horizontal, or even diagonal pipelines
- Flow abatement in the separation chamber via a special spiral pipe enables air, micro air bubbles, magnetic and non-magnetic dirt and sludge particles to be removed continuously in the event of very low pressure loss
- For use in apartment buildings, commercial properties, industry, local and distance heating networks
- Pump-controlled pressure holding with attached depressurised expansion vessel to accommodate expansion volumes and maintain constant pressure in closed heating, air-conditioning and cooling systems
- Supplied fully pre-assembled
- Heating and cooling systems with primary and secondary circuits or with separate groups and Pumps, such as Underfloor heating or Heat pumps, require optimised hydronic balancing
Technical data: - Operating pressure: max. 10 bar
- Operating temperature: max. 110°C
- Suitable for connection sizes: 22 mm, DN 20 (3/4”) to DN 40 (1 1/2”), and vertical: 22 mm and DN 20 (3/4”) to DN 25 (1”)
- Suitable for Spirotrap MBL from DN 32 (1 1/4")
- Fully automatic vacuum degasser for physical degassing of the system water in closed heating and cooling systems
- Compact and fully pre-assembled control and hydraulic unit, suitable for floor or wall fitting
- detachable, enclosed housing with sound insulation function
- For use with products with automatic make-up function
- DN15 (1/2”), IT
- For air separator Spirovent Solar DN20 (3/4") IT to DN40 (1 1/2") IT
- Not suitable for Spirotop (all versions) and Spirovent ("Auto Close” version)
- Temperature max.: 180°C