Vexve
- Technical data:
- Operating voltage: 230V/AC, 50 Hz
- Boiler output max.: 100 kW
- Suitable for charging valve ALV and TERMO 15-50 Termovar brass/AF, Thermokit LK 820/ACG
- Scope of delivery:
- Cover gaskets
- Suitable for Termovar AF/ADV changeover valves, LK 821
- Scope of delivery:
- Seal sets
- Screws
- Mixing valve for return flow boost with internal thread connections. In the case of hot water boilers, the automatic loading valve is built-in with or without buffer storage and works without external energy. It is used to maintain the return flow temperature. Due to an optimal boiler return temperature, falling below dew point and boiler sooting is prevented, which means that there is less environmental pollution and the service life of the boiler is extended. Using these loading valves, stratification in buffer storage can also be improved.
- Thermocouple can be turned in the direction of work under pressure and without tools
Technical data: - Max. operating temperature: 120°C
- Operating temperature max.: 110°C
- Max. operating pressure: 10 bar
- Angle of rotation: 90°
- Pre-assembled valve unit for solid fuel buffer storage systems to maintain the boiler return temperature. Due to optimal boiler return temperature, falling below dew point and boiler sooting is prevented, which means that there is less environmental pollution and the service life of the boiler is extended. Using the loading valve unit, stratification in buffer storage can also be improved.
Technical data: - Operating voltage: 230 V / AC, 50 Hz
- Max. flow rate: 2600 L/h
- Pre-assembled valve unit for solid fuel buffer storage systems to maintain the boiler return temperature. Due to optimal boiler return temperature, falling below dew point and boiler sooting is prevented, which means that there is less environmental pollution and the service life of the boiler is extended. Using the loading valve unit, stratification in buffer storage can also be improved.
Technical data: - Operating voltage: 230 V / AC, 50 Hz
- Max. flow rate: 2600 L/h
- Suitable for charge valve LK 823
- Operating temperature max.: 110°C
- Max. operating pressure: 10 bar
- Angle of rotation: 90°
- Suitable for charging valve ALV and TERMO 15-50 Termovar AF
- Scope of delivery:
- Cover gaskets - Suitable for Termo charge valve
- Suitable for charge valve unit TERMOVAR brass
- Suitable for LK 810 eco charge valve, thermokit, Termovar grey cast iron
- Suitable for charge valve unit TERMOVAR brass
- Suitable for charge valve unit TERMOVAR brass
- Suitable for grey cast iron mixer TERMOMIX model H, DN 15 (1/2") - DN 32 (1 1/4")
- Suitable for loading valve unit ACGE
- Double-acting backflow preventer
- Connections: DN40 (1½”) internal thread
- Suitable for charge valve unit TERMOVAR brass
- Suitable for charge valve unit TERMOVAR brass
- To fully seal the backflow preventer
- Suitable for charge valve unit TERMOVAR brass