Gas flow monitor

5 / 5 Gas flow monitor
Hauptbild
53 001 09
Gas installation package with flow switch, screw connections, ball valve + free gas leak detection spray
Immediately available
  • Consisting of:
    5 x gas flow monitors DN 25 (1"), 15-100 mbar, 4 m3/h
  • Flow direction from external to internal thread (E/I)

    10 x threaded screw connection, ø 22 mm Unipress connection (V or M contour), 1 3/8" IT

    5 x gas stop ball valve for single pipe meters, straight through, 1 3/8“ ET
  • For gauge counter G2.5-G6
Hauptbild
Multiple variants
Gas flow monitor
Immediately available
  • Model GST for domestic installation according to DVGW-VP305, as a measure to actively deter manipulation in accordance with TRGI
    Technical properties:
    Horizontal installation: for metal conductors and plastic pipes
    Vertical installation: only for metal conductors, flow direct from bottom upwards
    Operating pressure: 15-100 mbar
    Operating temperature: -20°C to +60°C
    Pressure loss: dp<0.5 mbar
    Overcurrent: VL <30 lt/h at 100 mbar
    External temperature resistance: 925 °C - 5 bar
    Internal temperature resistance: 200 °C
    Area of application: all gas types according to EN437 and DVGW G260/1
    Function:
    the flow monitor blocks the line when the flow rate selected is achieved. After the cause is rectified, pressure compensation occurs via an overflow opening, which enables the safety device to re-open.

    Construction:
    the internal springs do not come into contact with the flow of gas, which means they do not get dirty, ensuring a long service life. The overview opening is also protected in the open position to safeguard the re-opening function.
    !!! Particularly low pressure loss (< 0.5 mbar) !!!
  • Flow direction from internal to external thread (I/E)
Hauptbild
Multiple variants
Installation position “D”
Immediately available
  • Operating pressure: 15 - 100 mbar
  • Pressure loss: ≤ 0.5 mbar
  • Overflow rate: 2 - 30 l/h air
Hauptbild
Multiple variants
Gas flow monitors from external to internal thread
Immediately available
  • Model GST for domestic installation according to DVGW-VP305, as a measure to actively deter manipulation in accordance with TRGI
    Technical properties:
    Horizontal installation: for metal conductors and plastic pipes
    Vertical installation: only for metal conductors, flow direct from bottom upwards
    Operating pressure: 15-100 mbar
    Operating temperature: -20°C to +60°C
    Pressure loss: dp<0.5 mbar
    Overcurrent: VL <30 lt/h at 100 mbar
    External temperature resistance: 925 °C - 5 bar
    Internal temperature resistance: 200 °C
    Area of application: all gas types according to EN437 and DVGW G260/1
  • Flow direction from external to internal thread (E/I)
Hauptbild
Multiple variants
Gas-flow monitor GS PS 5 bar, installation position "Z"
Immediately available
  • Operating pressure: 15 - 100 mbar
  • Pressure loss: ≤ 0.5 mbar
  • Overflow rate: 2 - 30 l/h air