RESOL®
- Remote access to up to 2 controllers and integrated data recording
- Internet access to the system via VBus.net
- Connection to building management system via BACnet/IP or Modbus/TCP
- For simple solar systems and solid fuel boilers.
- For standard and high-efficiency recirculation pumps with PWM signal
- With 4 inputs and 2 outputs.
Functions:
- Allows convenient access to the controller via the operator’s local network. This provides access to the controller, setting of the system parameters and reading of data from any network station. The VBus®/LAN interface adapter is suitable for all controllers with RESOL VBus®.
Technical data: - Power supply: input voltage
- Plug-in power supply unit: 100 ... 240VAC (50 ... 60 Hz)
- The VBus®/USB adapter forms the interface between the controller and the PC. Equipped with a standard mini USB port, it facilitates fast transmission, representation and archiving of system data and setting of the controller parameters via the VBus®. A full version of the special RESOL ServiceCenter software is supplied.
Technical data: - Power supply: RESOL VBus®
- Data interfaces: VBus®
- The PSW Basic pump signal converter guarantees speed-regulated control of the PWM pump when changing from standard pumps to HE circulating pumps with PMW control, without replacing the controller.
- For solar and heating pumps
- Output signal PWM or 0-10 V
- Visualisation of system status
- Yield control
- Simplified fault diagnosis
- Used to visualise the data provided by the controller
- Displays the collector and storage tank temperature and the energy yield from the solar system
- Designed for easy connection to RESOL controllers via the VBus®
Alternative pump signal converter for standard solar pumps, PSW with HE pump, Wilo Yonos Para ST 25/7-180 ...
For recording the instantaneous solar irradiation intensity. ...
- Inputs: 8 inputs for PT1000,
PT500 or KTY temperature sensors,
1 V40 impulse input, 2 Grundfos
Direct Sensors™, 1 CS10 radiation sensor - Outputs: 4 semi-conductor relays, 1 floating
relay, 2 PWM outputs - Data output: RESOL VBus®,
SD card slot
- Suitable for RESOL and Viessmann up to year of manufacture 2011 (Vitosolic 100 and 200)
- Model: Pt 500
- Dimensions: ø 6 mm, length 2.5 m (silicone cable)
- Suitable for external mounting
- Dimensions: 68 x 111 x 40 mm
- With the HE check, the functions of the pump and the controller signals can be checked easily and quickly. The test device measures and generates both PWM signals in the range of 40 to 2000 Hz and 0-10-V control signals. PWM signals can also be sent and received simultaneously for testing of bidirectional pumps. The volume flow and the pump status are also displayed.
Delivery contents: - Measurement and signal cable for various pumps and controllers
- Storage bag
- For simple solar systems and solid fuel boilers
- For standard and high-efficiency recirculation pumps with PWM signal
- With 4 inputs and 2 outputs
The DeltaSol® CS Plus has been specially developed for the speed-controlled control of high-efficiency pumps in standard solar and heating systems. It has two PWM outputs as well as an input for a Grundfos DirectSensor ™ VFD, which allows accurate heat quantity counting. The commissioning menu leads you through the most important settings for the initial configuration in only eight steps.
Technical data:
- With 2 inputs and 2 outputs
- Equipped with two high-load relays to which an electric heating element of up to 3.6 kW (230 V~) can be connected
- Regulates the time and temperature-controlled re-heating of a hot water storage tank
- Expansion of the controller by 6 sensor inputs and 5 relay outputs
- LC display with 7-segment display
- Function control
- Used to visualise the data provided by the controller
- In the area of heating, the Smart Display SDFK shows the solid fuel boiler and storage tank temperature at the top / bottom and the pump status
- Display with 3 indicators for biomass boiler and storage tank temperature and pump status
- For solid fuel boiler
- For standard and high-efficiency recirculation pumps with PWM signal
- With 4 inputs and 2 outputs
The solid fuel boiler controller FK has been specially developed for systems with solid fuel boilers, water-fired stoves or pellet heaters. Thanks to the integrated PWM outputs, it can control two high-efficiency pumps in a speed-controlled manner.
With easily configurable options, the versatile software allows, for example, the control of an electronic mixer for backflow mixing, thermostatic post-heating, a target temperature control and much more.
Technical data:
- For connecting high-efficiency Circulation pumps to RESOL® Controls
- Scope of delivery:
- JST plugs
- Connection terminal
- Suitable for: DeltaSol, DeltaTherm
- Model: Pt1000
- Dimensions: 68 x 111 x 40 mm
- For complex solar systems and solid fuel boilers
- For standard and high-efficiency recirculation pumps with PWM signal
- With 4 inputs and 3 outputs
Technical data:
- For medium-sized solar systems and solid fuel boilers.
- For standard and high-efficiency recirculation pumps with PWM signal
- With 5 inputs and 4 outputs
Technical data:
- Internet access to the system via VBus.net
- Systems can be conveniently parametrised with the RESOL parametrisation tool RPT
- For all RESOL controller with VBus®
- The digital VFD Grundfos Direct Sensors™ measure temperature and volume flow with just one measuring element and transmit the measurements directly via the RESOL-VBus® protocol. Grundfos Direct Sensors™ are suitable for use in both caustic media and drinking water and are thus ideal for volume flow and heat quantity measurement in solar and heating systems.
Technical data: - Material: Stainless steel 1.4408
- Protection type: IP20
- Suitable for DeltaSol, DeltaTherm
- Model: PT1000 sensor
- Dimensions: ø 6 mm, length 1.5 m (silicone line)
- Analogue
- Scope of delivery:
- Fittings
- Insert
- Connection cables
- For medium-sized solar systems and solid fuel boilers.
- With 8 inputs and 7 outputs.
- Housing: plastic, PC-ABS and PMMA
- For simple solar systems and solid fuel boilers
- For standard and high-efficiency recirculation pumps with PWM signal
- With 5 inputs and 5 outputs
Technical data:
- For complex solar systems and solid fuel boilers
- For standard and high-efficiency recirculation pumps with PWM signal
- With 4 inputs and 3 outputs
Technical data:
System controller for solar and heating systems DeltaSol® MX ...
- The PSW Basic pump signal converter guarantees speed-regulated control of the PWM pump when changing from standard pumps to HE circulating pumps with PMW control, without replacing the controller.
- For solar and heating pumps
- Output signal PWM or 0-10 V
- It is connected to the controller’s VBus® and emits a visual signal via a red LED if a fault occurs. The AM1 also has a relay output which allows connection to building control technology. A collective fault message can then be issued in the event of a fault. Depending on the controller and sensors, various fault statuses can be displayed, such as sensor failures, overpressure or underpressure faults and flow rate or dry running faults. This provides the optimal guarantee of output stability and operating safety of the system.
Technical data: - Outputs: 1 floating relay
- Switching capacity: max. 30 V (DC), 1A; 125 V~ (AC), 0.5 A
- Used to visualise the data provided by the controller
- In the area of heating, the Smart Display SDFK shows the solid fuel boiler and storage tank temperature at the top / bottom and the pump status
- Display with 3 indicators for biomass boiler and storage tank temperature and pump status
- The digital VFD Grundfos Direct Sensors™ measure temperature and volume flow with just one measuring element and transmit the measurements directly via the RESOL-VBus® protocol. Grundfos Direct Sensors™ are suitable for use in both caustic media and drinking water and are thus ideal for volume flow and heat quantity measurement in solar and heating systems.
Technical data: - Material: Stainless steel 1.4408
- Protection type: IP20
- General accessories for solar stations
- Black EPDM drain hose, heat resistant
Fits all standard DN 20 (3/4") safety valves - Quick and easy installation
- With 1 input and 1 output
The RESOL TT1 thermostat compares the temperature recorded by a sensor with the switch-on temperature setting. If this temperature is not reached (heating mode), the relay switches on. When it is exceeded, the relay switches off. Depending on the switch-on and switch-off temperature, the controller works in heating or cooling mode. Electronic temperature controller (thermostat) with LC combination display to show the current temperature and the parameter settings (menu-controlled).
Delivery contents: - Incl. 1 sensor Pt1000 (FRP6)
Technical data: - Inputs: 1 temperature sensor Pt1000