GOK: Top Categories

GOK

24 / 195
Hauptbild
Multiple variants
Hose cable for multi-bottle systems
Immediately available
  • High-pressure PS 30, DIN-DVGW-tested
  • Hose lines are equipped with a clip (except KLF)
    Connections:
  • On one side, large-bottle (GF), small-bottle (KLF) connection or combi (union nut), on the other large-bottle (GF) external thread or RST
Hauptbild
Multiple variants
Replacement light for ASF vacuum leak indicator
Immediately available
  • Suitable for ASF vacuum leak indicator
Hauptbild
58 000 01
Gas cylinder valve for butane gas cylinders M16x1.5
Immediately available
  • For connection to propane and butane gas bottles up to 5 kg
  • With safety blow-off valve, response pressure 14 bar
  • Connection thread: GAZ (M16x1.5 ET) x ET KLF (small bottle connection)
Hauptbild
58 001 07
Control valve set B 200 RVS15 12kg/h 50mbar
Immediately available
  • Can only be used for exterior mounting downstream of a
    pre-stage controller with SAV value = 2.0 bar
  • Consisting of: Insulating piece, shut-off valve,
    gas filter insert, isolating screw connections,
    low pressure controller12 kg/h with safety shut-off
    valve OPSO (SAV) and safety blow-off valve PRV,
    Two junction pieces for soldering connection
    and hot-dip galvanised protective box
    (H x W x D: 460 x 310 x 155 to 215 mm)
  • Output: 12 kg/h
Hauptbild
Multiple variants
Caravan controller PS 16 bar
Immediately available
  • For connection to gas cylinders, for pressure regulation based on nominal pressure
    of the gas appliance
  • KLF x T 1/4 LH-KN
  • Outlet pressure: 30 mbar
    Consisting of:
Hauptbild
58 004 08
Euro Set No. 1-4
Immediately available
  • For connecting a pressure compensator with German connection to liquid gas cylinders that are standard on the European market
  • Consisting of 4 adapter fittings
Hauptbild
58 004 28
Pre-stage controller PS 25 bar 24 kg/h 0.7 bar, POL x RVS 15, Shut-off pressure SAV: 1.0 bar
Immediately available
  • For direct connection to LPG tanks
  • Input: POL connection
  • Output:
    Cutting-ring connection RVS 15 mm, 0.7 bar
    with OPSO (SAV) safety shut-off valve and
    safety blow-off valve PRV
Hauptbild
58 001 75
Union G 1/4" x 8mm
Immediately available
  • Mounted with nut and cutting ring
  • DN 8 (1/4”) LH-union nut x RST 8 (union nut)
Hauptbild
Multiple variants
GOK cylinder system with OPSO/UPSO, type AUV, with automatic switchover device
Only a few items left in stock
  • For connection to gas cylinders with a filling weight of 33 kg, for pressure regulation to the nominal pressure of the gas appliance
  • Also suitable for commercial use
  • Cylinders can be changed without interrupting operation
Hauptbild
Multiple variants
Caravan controller EN 61
Immediately available
  • For connection to liquid gas cylinders up to 14 kg
  • KLF x DN 8 (1/4”) LH-KN
  • Outlet pressure: 50 mbar
Hauptbild
Multiple variants
Double ball foot valve
Immediately available
  • Backflow preventer for oil suction pipes
    to DIN EN 12514-2
  • With spacer spring
Hauptbild
Multiple variants
Gas bottle cabinets for 33 kg bottles
Delivery item
  •  Material: hot-dip galvanised sheet steel
  • Lockable: square lock including square keys
  • Suitable for all 33 kg gas bottles
Hauptbild
30 006 30
GOK two pipe filter 3/8" SIKU-70µm UA 8/10mm
Immediately available
  • Including bracket and connector set for 8/10 mm Cu pipe
  • Housing made of die-cast zinc, bichromated
  • With Siku insert: 70 µm
Hauptbild
Multiple variants
Cutting ring screw connection, special size GEV
Immediately available
  • 10 mm x R DN 6 (1/8")
  • Cylindrical
Hauptbild
58 004 23
Gas hose 300 mm 30 bar Combi connection on one side 12 mm pipe support on the other side
Immediately available
Hauptbild
32 000 51
Tank level indicator digital GOK type Smartbox 3 incl. probe
Only a few items left in stock
  • Display device for dry and protected rooms
  • 1 relays with NC and NO contact max. 250 V AC, 3.5 A
  • Protection type: IP 30
Hauptbild
32 041 16
Filling tube closure NF 2" x 72 x 1/8" Shell (A)
Immediately available
  • For Austria
Hauptbild
32 041 48
Vacuum testing device Model UPE-300
Immediately available
  • The test duration according to TRÖI chapter 4.10.4.2. "Tightness test with negative pressure" is:
    - 10 minutes for above-ground pipes
    - 30 minutes for underground pipes
  • Consisting of a connection block with integrated shut-off valve, in which a vacuum gauge and a vacuum limiter are mounted
  • The suction pressure of the suction pump is limited to the specified test vacuum of -0.3 bar
Hauptbild
Multiple variants
Hose breakage protection for medium pressure
Immediately available
  • Hose breakage protection devices prevent excess gas from escaping in the event of damage or hose loosening and close up the passage of gas as soon as the prescribed operating quantity is exceeded max. 10% above the nominal flow rate.
    Fitted between controller and hose. Commercial for hoses >400 mm and private >1500 mm. Exclusively for outdoor use.
  • For trade and industry
  • Input: DN 10 (G 3/8”) LH-union nut
Hauptbild
58 001 18
Pre-stage control D 68 RVS 15 24kg/h 4bar
Immediately available
  • For direct connection to gas containers
  • Input: POL connection
  • Output: Cutting-ring connection RVS 15 mm with safety shut-off valve OPSO (SAV) and safety blow-off valve PRV
Hauptbild
32 041 03
Filler tube closure NF 2" x 2" m (B)
Immediately available
  • For Benelux
Hauptbild
Multiple variants
House in-feed with main shut-off device PS 5 bar
Immediately available
  • For installation in liquefied petrochemical plants for ground-level house systems
  • Incl. ball valve with TAE and wall connection set inside
  • RST22: Incl. heat-shrink tubing (length: 500 mm)
Hauptbild
58 000 16
Stainless steel corrugated hose line type MWS, G1/4"LH-ÜWM x IT Rp1/2", length 1000 mm
Immediately available
  • For the stress-free connection of fittings to consumer appliances or pipelines
  • Maximum permissible pressure: PS 1 bar
  • DN 8 (1/4") LH union nut x IG RP DN 15 (1/2")
Hauptbild
58 004 27
Pre-stage controller PS 25 bar, 24 kg/h 0.7 bar, POL x RVS 15, Shut-off pressure SAV: 2.0 bar
Immediately available
  • For direct connection to LPG tanks
  • Input: POL connection
  • Output:
    Cutting-ring connection RVS 15 mm, 0.7 bar
    with OPSO (SAV) safety shut-off valve
    and safety blow-off valve PRV